Feature
Smart Monitoring Platform
Thanks to the smart monitoring platform, this inverter support remotely shutdown immediately when accident occurs. Setting parameters and FW update remotely, which makes PV plant O&M easier.
Input Side
|
||||||
Max. DC Input Power (kW)
|
91 | 97.5 | 104 | 135 | 150 | 150 |
Max. DC Input Voltage (V)
|
1000 | |||||
Start-up DC Input Voltage (V)
|
250
|
|||||
MPPT Operating Range (V)
|
200-850
|
|||||
Max. DC Input Current (A)
|
40+40+40+40
|
40+40+40+40+40+40 | ||||
Max. Short Circuit Current (A)
|
60+60+60+60
|
60+60+60+60+60+60 | ||||
No.of MPP Trackers
|
4
|
6 | ||||
No.of Strings per MPP Tracker
|
4+4+4+4
|
4+4+4+4+4+4 | ||||
Output Side
|
||||||
Rated Output Power (kW)
|
70 | 75 | 80 | 90 | 100 | 110 |
Max. Active Power (kW)
|
77 | 82.5 | 88 | 99 | 110 | 121 |
Rated Output Voltage/Range (V)
|
3L/N/PE 220/380V,230/400V
|
|||||
Rated Grid Frequency (Hz)
|
60Hz/50Hz(Optional)
|
|||||
Operating Phase
|
Three Phase
|
|||||
Rated AC Grid Output Current (A)
|
106.1/101.5 | 113.6/108.7 | 121.2/115.9 | 136.4/130.4 | 151.5/144.9 | 166.7/159.4 |
Max. AC Output Current (A)
|
116.7/111.6 | 125/119.6 | 133.3/127.5 | 150/143.5 | 166.7/159.4 | 183.3/175.4 |
Output Power Factor
|
0.8 leading to 0.8 lagging
|
|||||
Total Harmonics Current Distortion (THDi)
|
<3%
|
|||||
DC Injection Current (mA)
|
<0.5%
|
|||||
Grid Frequency Range
|
45~55 or 55~65(Optional) | |||||
Efficiency
|
||||||
Max. Efficiency
|
98.8%
|
|||||
Euro Efficiency
|
98.3%
|
|||||
MPPT Efficiency
|
>99%
|
|||||
Protection
|
||||||
DC Reverse-Polarity Protection
|
Yes
|
|||||
AC Short Circuit Protection
|
Yes
|
|||||
AC Output Overcurrent Protection
|
Yes
|
|||||
Output Overvoltage Protection
|
Yes
|
|||||
Insulation Resistance Protection
|
Yes
|
|||||
Ground Fault Monitoring
|
Yes
|
|||||
Anti-islanding Protection
|
Yes
|
|||||
Temperature Protection
|
Yes
|
|||||
Integrated DC Switch
|
Yes
|
|||||
Remote Software Upload
|
Yes
|
|||||
Remote Change of Operating Parameters
|
Yes
|
|||||
Surge Protection
|
DC Type II / AC Type II
|
|||||
General Data
|
||||||
Cabinet Size (WxHxD mm)
|
826*516*312.7 (Excluding Connectors and Brackets)
|
|||||
Weight (kg)
|
81
|
|||||
Topology
|
Transformerless
|
|||||
Internal Consumption
|
<1W (Night)
|
|||||
Running Temperature
|
-25-65℃, >45℃ Derating
|
|||||
Ingress Protection
|
IP65
|
|||||
Noise Emission (Typical)
|
≤55 dB
|
|||||
Cooling Concept
|
Smart Cooling
|
|||||
Permissible Altitude (m)
|
4000
|
|||||
Grid Connection Standard
|
IEC 61727,IEC 62116,CEI 0-21,CEI 0-16,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105,VDE-AR-N 4110 | |||||
Operating Surroundings Humidity
|
0-100%
|
|||||
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
|||||
Features
|
||||||
Display
|
LCD240*160
|
|||||
Interface
|
RS485/RS232/Wifi/LAN
|
Certification