Feature
Battery Input Data | |||||
Battery Type | Lead-acid or Lithium-ion | ||||
Battery Voltage Range (V) | 20~30 | 40~60 | 40~60 | 40~60 | 40~60 |
Max. Charging Current (A) | 140A | 70A | 90A | 120A | 135A |
Max. Discharging Current (A) | 140A | 70A | 90A | 120A | 135A |
Charging Curve | 3 Stages / Equalization | ||||
External Temperature Sensor | Yes | ||||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS |
PV String Input Data | |||||
Max. DC Input Power (W) | 3900W | 3900W | 4680W | 6500W | 7800W |
PV Input Voltage (V) | 370V (125V~500V) | ||||
MPPT Range (V) | 150~425V | ||||
Start-up Voltage (V) | 250~425V | ||||
PV Input Current (A) | 13A | 13A+13A | |||
Max. PV ISC (A) | 17A | 17A+17A | |||
No.of MPPT Trackers | 1 | 2 | |||
No.of Strings Per MPPT Tracker | 1 | 1+1 |
AC Output Data | ||||
Rated AC Output and UPS Power (W) | 3000W | 3600W | 5000W | 6000W |
Max. AC Output Power (W) | 3300W | 3690W | 5500W | 6600W |
Peak Power (off grid) | 2 times of rated power, 10 S | |||
AC Output Rated Current (A) | 13.6 | 16.4 | 22.7 | 27.3 |
Max. AC Current (A) | 15 | 18 | 25 | 30 |
Max. Continuous AC Passthrough (A) | 35A | 40A | ||
Power Factor | 0.8 leading to 0.8 lagging | |||
Output Frequency and Voltage | 50/60Hz; 220/230 / 240Vac (single phase) | |||
Grid Type | Single Phase | |||
Current Harmonic Distortion | THD<3% (Linear load<1.5%) |
Efficiency | |
Max. Efficiency | 97.60% |
Euro Efficiency | 96.50% |
MPPT Efficiency | 99.90% |
Protection | |
PV Input Lightning Protection | Integrated |
Anti-islanding Protection | Integrated |
PV String Input Reverse Polarity Protection | Integrated |
Insulation Resistor Detection | Integrated |
Residual Current Monitoring Unit | Integrated |
Output Over Current Protection | Integrated |
Output Shorted Protection | Integrated |
Output Over Voltage Protection | Integrated |
Surge protection | DC Type II / AC Type II |
Certifications and Standards | |
Grid Regulation |
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
|
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
General Data | |
Operating Temperature Range (℃) | -45~60℃, >45℃ Derating |
Cooling | Natural cooling |
Noise (dB) | <30 dB |
Communication with BMS | RS485; CAN |
Weight (kg) | 14 |
Size (mm) | 330W×433H×238D |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
Warranty | 5 years |
Certification