Feature
|
Input Side
|
|||||
|
Max. DC Input Power (kW)
|
180 | 187.5 | 195 | 202.5 | 204 |
|
Max. DC Input Voltage (V)
|
1100 | ||||
|
Start-up DC Input Voltage (V)
|
250
|
||||
|
MPPT Operating Range (V)
|
200-1000
|
||||
|
Max. DC Input Current (A)
|
40+40+40+40+40+40+40+40
|
||||
|
Max. Short Circuit Current (A)
|
60+60+60+60+60+60+60+60
|
||||
|
No.of MPP Trackers
|
8
|
||||
|
No.of Strings per MPP Tracker
|
4+4+4+4+4+4+4+4
|
||||
|
Output Side
|
|||||
|
Rated Output Power (kW)
|
120 | 125 | 130 | 135 | 136 |
|
Max. Active Power (kW)
|
132 | 135 | 135 | 135 | 136 |
|
Rated Output Voltage/Range (V)
|
3L/N/PE 220/380V,230/400V
|
||||
|
Rated Grid Frequency (Hz)
|
60Hz/50Hz(Optional)
|
||||
|
Operating Phase
|
Three Phase
|
||||
|
Rated AC Grid Output Current (A)
|
181.9/174 | 189.4/181.2 | 197/188.5 | 204.6/195.7 | 206.1/197.2 |
|
Max. AC Output Current (A)
|
200/191.4 | 204.6/195.7 | 204.6/195.7 | 204.6/195.7 | 206.1/197.2 |
|
Total Harmonics Current Distortion (THDi)
|
<3%
|
||||
|
DC Injection Current (mA)
|
<0.5%
|
||||
|
Grid Frequency Range
|
45~55 or 55~65(Optional) | ||||
|
Efficiency
|
|||||
|
Max. Efficiency
|
98.8%
|
||||
|
Euro Efficiency
|
98.3%
|
||||
|
MPPT Efficiency
|
>99%
|
||||
|
Protection
|
|||||
|
DC Reverse-Polarity Protection
|
Yes
|
||||
|
AC Short Circuit Protection
|
Yes
|
||||
|
AC Output Overcurrent Protection
|
Yes
|
||||
|
Output Overvoltage Protection
|
Yes
|
||||
|
Insulation Resistance Protection
|
Yes
|
||||
|
Ground Fault Monitoring
|
Yes
|
||||
|
Anti-islanding Protection
|
Yes
|
||||
|
Temperature Protection
|
Yes
|
||||
|
Integrated DC Switch
|
Yes
|
||||
|
Remote Software Upload
|
Yes
|
||||
|
Remote Change of Operating Parameters
|
Yes
|
||||
|
Surge Protection
|
DC Type II / AC Type II
|
||||
|
General Data
|
|||||
|
Cabinet Size (WxHxD mm)
|
1006*516*325.5(Excluding Connectors and Brackets)
|
||||
|
Weight (kg)
|
103
|
||||
|
Topology
|
Transformerless
|
||||
|
Internal Consumption
|
<1W (Night)
|
||||
|
Running Temperature
|
-25-60℃, >45℃ Derating
|
||||
|
Ingress Protection
|
IP65
|
||||
|
Noise Emission (Typical)
|
≤65 dB
|
||||
|
Cooling Concept
|
Smart Cooling
|
||||
|
Permissible Altitude (m)
|
4000
|
||||
|
Grid Connection Standard
|
IEC 61727,IEC 62116,CEI 0-21,CEI 0-16,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105,VDE-AR-N 4110 | ||||
|
Operating Surroundings Humidity
|
0-100%
|
||||
|
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
||||
|
Features
|
|||||
|
Display
|
LCD240*160
|
||||
|
Interface
|
RS485/RS232/Wifi/LAN
|
||||
Certification