Feature
Input Side
|
||||||||||
Max. DC Input Power (kW)
|
1.3
|
2 | 2.6 | 2.9 | 3.3 | 3.5 | 3.9 | 4.3 | 4.7 | 5.2 |
Max. DC Input Voltage (V)
|
550
|
|||||||||
Start-up DC Input Voltage (V)
|
80
|
|||||||||
MPPT Operating Range (V)
|
70-500
|
|||||||||
Max. DC Input Current (A)
|
13 | |||||||||
Max. Short Circuit Current (A)
|
19.5 | |||||||||
No.of MPP Trackers
|
1 | |||||||||
No.of Strings per MPP Tracker
|
1 | |||||||||
Output Side
|
||||||||||
Rated Output Power (kW)
|
1 | 1.5 | 2 | 2.2 | 2.5 | 2.7 | 3 | 3.3 | 3.6 | 4 |
Max. Active Power (kW)
|
1.1 | 1.65 | 2.2 | 2.42 | 2.75 | 2.97 | 3.3 | 3.63 | 3.96 | 4.4 |
Rated Output Voltage/Range (V)
|
3L/N/PE 220/230V(Optional) | |||||||||
Rated Grid Frequency (Hz)
|
50/60Hz(Optional) | |||||||||
Operating Phase
|
Single Phase
|
|||||||||
Rated AC Grid Output Current (A)
|
4.6/4.4 | 6.8/6.5 | 9.1/8.7 | 10/9.6 | 11.4/10.9 | 12.3/11.8 | 13.7/13.1 | 15/14.4 | 16.4/15.7 |
18.2/17.4
|
Max. AC Output Current (A)
|
5/4.8 | 7.5/7.2 | 10/9.6 | 11/10.6 | 12.5/12 | 13.5/13 | 15/14.4 | 16.5/15.8 | 18/17.3 |
20/19.2
|
Output Power Factor
|
0.8 leading to 0.8 lagging
|
|||||||||
Total Harmonics Current Distortion (THDi)
|
<3%
|
|||||||||
DC Injection Current (mA)
|
<0.5%
|
|||||||||
Efficiency
|
||||||||||
Max. Efficiency
|
97.3% | 97.3% | 97.3% | 97.3% | 97.3% | 97.3% | 97.5% | 97.5% | 97.5% | 97.5% |
Euro Efficiency
|
97.1% | 97.1% | 97.1% | 97.1% | 97.1% | 97.1% | 97.3% | 97.3% | 97.3% | 97.3% |
MPPT Efficiency
|
>99%
|
|||||||||
Protection
|
||||||||||
DC Reverse-Polarity Protection
|
Yes
|
|||||||||
AC Short Circuit Protection
|
Yes
|
|||||||||
AC Output Overcurrent Protection
|
Yes
|
|||||||||
Output Overvoltage Protection
|
Yes
|
|||||||||
Insulation Resistance Protection
|
Yes
|
|||||||||
Ground Fault Monitoring
|
Yes
|
|||||||||
Anti-islanding Protection
|
Yes
|
|||||||||
Temperature Protection
|
Yes
|
|||||||||
Integrated DC Switch
|
Yes
|
|||||||||
Remote Software Upload
|
Yes
|
|||||||||
Remote Change of Operating Parameters
|
Yes
|
|||||||||
Surge Protection
|
DC Type II / AC Type II
|
|||||||||
General Data
|
||||||||||
Cabinet Size (WxHxD mm)
|
280*310*184(Excluding Connectors and Brackets)
|
|||||||||
Weight (kg)
|
4.8 | |||||||||
Topology
|
Transformerless
|
|||||||||
Internal Consumption
|
<1W (Night)
|
|||||||||
Running Temperature
|
-25-65℃, >45℃ Derating
|
|||||||||
Ingress Protection
|
IP65
|
|||||||||
Noise Emission (Typical)
|
≤35 dB
|
|||||||||
Cooling Concept
|
Smart Cooling
|
|||||||||
Permissible Altitude (m)
|
2000
|
|||||||||
Warranty
|
5 Years
|
|||||||||
Grid Connection Standard
|
OEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,G98,G99,VDE-AR-N 4105 | |||||||||
Operating Surroundings Humidity
|
0-100%
|
|||||||||
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
|||||||||
Features
|
||||||||||
Display
|
LCD1602
|
|||||||||
Interface
|
RS485/RS232/Wifi/LAN
|
Certifications